It is mandatory to procure user consent prior to running these cookies on your website. Ogni giorno il sito viene aggiornato con nuovi manuali uso. Tipo di impianto: Pompa di calore. How do I fix an error E654 on my Samsung split AC? I have a error code E500 contact failure on IPM of inverter PBA1 That has been 3 months ago. Error code related to the Communications / Settings / HW (cont. Were you able to get this resolved? Required fields are marked *. 29/07/2017 0 risposte Napoli ID richiesta: 142797. Hi did you ever find out how to correct the E-201 error I have the same problem i have it wired correctly as per diagram ..Thanks. I have a problem in Samsung inverter split a.c unit.indoor unit show error E109.What its means and what should I do.please help. Please tell me about 10ch error in Samsung 1.5ton. Raise the desired temperature than the current one? Check again at the state of Cooling / Fan only / Heating. E-101: Indoor unit communication error. Is the operation selected among one of Auto / Dry / Turbo / Sleeping? Samsung Supporto IT Your email address will not be published. This error occurs when the option settings of the master and slave wired remote controls are different from each other. Auto restart function is the convenient function where the operation state is memorized in the Memory IC during the blackout and the operation restarts when the power comes back, Samsung Wind Free™ Air Conditioner : Fast Cooling Test, Samsung Split Type Air Conditioner Service Manual PDF, Samsung Multi Air Conditioner Service Manual PDF, DVM S Service Manuals_DVM S Outdoor Unit Service Manual PDF, Samsung official site: https://www.samsung.com/levant/air-conditioners. Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. Il s'agit d'une panne technique. These cookies will be stored in your browser only with your consent. Necessary cookies are absolutely essential for the website to function properly. Everyone I talk to does not install this brand . Is the operation selected among the Dry / Turbo / Sleeping / Fan only Mode. Le bouton Power reste enfoncé en permanence. © 2014-2020 ACErrorCode.com. This website uses cookies to improve your experience while you navigate through the website. E-149: Error due to AHU master indoor unit sensor setting. Riavvio Automatico > In caso di interruzione dell’alimentazione elettrica, le unità, al ripristino procedono a … … Is the detection part of the indoor unit blocked? C ontactez le service client Samsung . Is the selected temperature too low? un condizionatore de longhi pac we 125 eco usato. E-102: Communication error between indoor unit and outdoor unit. My aircon display lights starts blinking and out comes warm air. Does it interfered with the radio of neon sign? The temperature setting is not required since the wind volume set automatically. We also use third-party cookies that help us analyze and understand how you use this website. FAQ su Samsung Climatizzatori. (during heating). Is there any direct light on the outdoor unit or any obstacle against it? Prohibit starting during operation of the Crack case heater, Error due to repeated communication address, Error on room temperature sensor of indoor unit (Short or Open), Error on EVA IN sensor of indoor unit (Short or Open), Error on EVA OUT sensor of indoor unit (Short or Open), Communication error sends from indoor unit, Indoor unit EEV open failure(When 2* detection), Indoor unit EEV close failure(When 2“ detection), Indoor unit floating S/V error(When 2“ detection), Error on thermal fuse of indoor unit (Open), Communication error between indoor unit and outdoor unit (Pre tracking failure or when actual number of indoor units are different from the indoor unit quantity setting on the outdoor unit) Error due to communication tracking failure after initial power supply (The error occurs with the failure regardless of the number of devices), Communication error between indoor and outdoor unit (When not received in every room after completing the tracking), Communication error between outdoor unit inv - main micom (For PF #4~#6 controller, error will be determined from the time when compressor turns on), Error on outdoor temperature sensor (Short or Open), Error on outdoor COND OUT sensor (Short or Open), Digital comp.1 discharge temperature sensor(Short or Open), Fixed comp.1 discharge temperature sensor(Short or Open), Fixed comp.2 discharge temperature sensor(Short or Open), Fixed comp.3 discharge temperature sensor(Short or Open), Fixed compl Discharge temperature sensor breakaway, Fixed comp2 Discharge temperature sensor breakaway, Fixed comp3 Discharge temperature sensor breakaway, Digital compl Sump temperature sensor breakaway. Is the filter clogged with dust or dirty? Soluzioni e Suggerimenti, Scarica il Manuale, Contattaci. C ontactez le service client Samsung … Out of these, the cookies that are categorized as necessary are stored on your browser as they are essential for the working of basic functionalities of the website. Unplug and plug again the power source for 2 minutes. Display Significato dei codici d'errore visualizzati sull'unità interna del condizionatore. Called the person who installed it and he tells me he will come and look at . -Input sensor error. Hi Julie, Error codes: Description: Ch: Prohibit starting during operation of the Crack case heater: E108: Error due to repeated communication address: E121: Error on room temperature sensor of indoor unit (Short or Open) E122: Error on EVA IN sensor of indoor unit (Short or Open) E123: Error on EVA OUT sensor of indoor unit (Short or … C ontactez le service client Samsung . Non riesco a trovarlo su nessun sito. Need information on the error code of Samsung cassette air conditioner and the solutions of repairs, I have an ac dvm system outdoor supply five indoors four are working well but is showing error code e153 have tried to replace float switch but sometimes it can work for a week then it’s bring again the error. ); Trouble: The wind comes out but the heating/cooling is not performed. Soluzioni e Suggerimenti, Scarica il Manuale, Contattaci. nel Supporto Samsung. Mauro. E-216: When indoor unit is not installed to a MCU port but the switch on the port is set to On. | View our. E-163: Indoor unit’s remote controller option input is Incorrect or missing. Sensor Error (Open/Short Error), Inverter Compressor Discharge Temp, sensor Error (Open/Short Error), Outdoor unit - indoor unit communication wire miss connection, Outdoor unit refrigerant Full leakage {Gas leak), (Inverter) Heatsink temperature over Error, Communication error between Indoor unit and wired remote control, Communication error between Master and Slave wired remote control, Error of setting option for wired remote control COM2, Communication error between wired remote control < -> indoor unit/ventilation system (ERV) (When communication has stopped for 3 minutes after detecting indoor unit/ventilation system (ERV) and wired remote control), Tracking 10 or more errors between wired remote control < -> indoor unit/ventilation system (ERV). Joseph, Your email address will not be published. Essendo suddetto … - Exceeded maximum no. Condizionatore Samsung errore E4: cosa significa. Ricerca guasti DAIKIN – VERIFICHE ED OPERAZIONI DEVONO ESSERE ESEGUITE DA TECNICI QUALIFICATPECIALIZZATI. E-217: hen indoor unit is connected to a MCU port but indoor unit is assigned to a MCU and the switch on the port is set to Off, E-218: When there’s at least one or more actual number of indoor unit connection compared to number of indoor units assigned to MCU, E-219: Error on temperature sensor located on MCU intercooler inlet, E-220: Error on temperature sensor located on MCU intercooler outlet, E-221: Error on outdoor temperature sensor of outdoor unit, E-231: Error on COND OUT temperature sensor of main outdoor unit, E-251: Error on discharge temperature sensor of compressor 1, E-257: Error on discharge temperature sensor of compressor 2, E-262: Discharge temperature sensor of compressor 1 is detached from the sensor holder on the pipe, E-263: Discharge temperature sensor of compressor 2 is detached from the sensor holder on the pipe, E-266: Top sensor of compressor 1 is detached, E-267: Top sensor of compressor 2 is detached, E-269: Suction temperature sensor is detached from the sensor holder on the pipe, E-276: Error on top sensor of compressor 1 (Short or Open), E-277: Error on top sensor of compressor 2 (Short or Open), E-291: Refrigerant leakage or error on high pressure sensor (Short or Open), E-296: Refrigerant leakage or error on low pressure sensor (Short or Open), E-308: Error on suction temperature sensor (Short or Open), E-311: Error on temperature sensor of double layer pipe/liquid pipe(sub heat exchanger) (Short or Open), E-321: Error on EVI (ESC) IN temperature sensor (Short or Open), E-322: Error on EVI (ESC) OUT temperature sensor (Short or Open), E-323: Error on suction sensor 2 (Short or Open), E-346: Error due to operation failure of Fan2, E-347: Motor wire of Fan2 is not connected, E-348: Lock error on Fan2 of outdoor unit, E-353: Error due to overheated motor of outdoor unit’s Fan2, E-355: Error due to overheated IPM of Fan2, E-361: Error due to operation failure of inverter compressor 2, E-364: Error due to over-current of inverter compressor 2, E-365: V-limit error of inverter compressor 2, E-366: Error due to over voltage /low voltage of inverter PBA2, E-367: Error due to unconnected wire of compressor 2, E-368: Output current sensor error of inverter PBA2, E-369: DC voltage sensor error of inverter PBA2, E-374: Heat sink temperature sensor error of inverter PBA2, E-385: Error due to input current of inverter 2, E-386: Over-voltage/low-voltage error of Fan2, E-389: V-limit error on Fan2 of compressor, E-393: Output current sensor error of Fan2, E-399: Heat sink temperature sensor error of Fan2, E-400: Error due to overheat caused by contact failure on IPM of Inverter PBA2, E-407: Compressor operation stop due to high pressure protection control, E-410: Compressor operation stop due to low pressure protection control or refrigerant leakage, E-416: Compressor operation stop due to discharge temperature protection control, E-425: Phase reversal or phase failure (3Ø outdoor unit wiring, R-S-T-N ), connection error on 3 phase input, E-428: Compressor operation stop due abnormal compression ratio, E-438: EVI (ESC) EEV leakage or internal leakage of intercooler or incorrect connector insertion of EVI, E-440: Heating mode restriction due to high air temperature, E-441: Cooling mode restriction due to low air temperature, E-442: Refrigerant charing restriction in heating mode when air temperature is over 15 °C, E-443: Operation prohibited due to low pressure, E-446: Error due to operation failure of Fan1, E-447: Motor wire of Fan1 is not connected, E-452: Error due to ZPC detection circuit problem or power failure, E-453: Error due to overheated motor of outdoor unit’s Fan1, E-455: Error due to overheated IPM of Fan1, E-461: Error due to operation failure of inverter compressor 1, E-462: Compressor stop due to full current control or error due to low current on CT2, E-464: Error due to over-current of inverter compressor 1, E-465: V-limit error of inverter compressor 1, E-466: Error due to over voltage /low voltage of inveter PBA1, E-467: Error due to unconnected wire of compressor 1, E-468: Output current sensor error of inverter PBA1, E-469: DC voltage sensor error of inver PBA1, E-474: Heat sink temperature sensor error of inverter PBA1, E-485: Error due to input current of inverter 1, E-486: Error due to over voltage/low voltage of Fan, E-489: V-limit error on Fan1 of compressor, E-493: Output current sensor error of Fan1, E-499: Heat sink temperature sensor error of Fan1, E-500: Error due to overheat caused by contact failure on IPM of Inverter PBA1, E-503: Error due to alert the user to check if the service valve is closed, E-504: Error due to self diagnosis of compressor operation, E-505: Error due to self diagnosis of high pressure sensor, E-506: Error due to self diagnosis of low pressure sensor, E-560: Outdoor unit’s option switch setting error (when iinappropriate option switch is on), E-563: Error due to module installation of indoor unit with old version (Micom version needs to be checked), E-573: Error due to using single type outdoor unit in a module installation, E-601: Communication error between remote controller and the DVM Hydro unit / Hydro unit HT, E-602: Communication error between master and slave remote controller, E-604: Tracking error between remote controller and the DVM Hydro unit / Hydro unit HT, E-618: Error due to exceeding maximum numbers of Hydro unit installation (16 units), E-627: Error due to exceeding maximum numbers of wired remote controller installation (2 units), E-628: DMS↔Transmitter Communication Error, E-630: ERV wire remote controller normal ventilation option set error, E-631: ERVWire Remote controller auto ventilation option set error, E-632: Error when input the pulse except set the value of Pulse Width by PIM, E-633: Error caused by installing mixed models, E-652: Two wired remote controllers have been set to Master mode (COM1 wiring), E-653: Remote controller’s temperature sensor is disconnected or has problem, E-654: Data error on remote controller (Memory read/write error), E-701: Floating switch error on the indoor unit (1st detection), E-702: Error due to closed EEV of indoor unit (1st detection), E-703: Error due to opened EEV of indoor unit (1st detection), E-901: Error on the sensor of water inlet pipe (Short or Open), E-902: Error on the sensor of water outlet pipe (Short or Open), E-904: Error on water tank (Short or open), E-907: Error due to pipe rupture protection, E-908: Error due to freeze prevention (Re-operation is possible), E-909: Error due to freeze prevention (Re-operation is impossible), E-910: Water temperature sensor on water outlet pipe is detached, E-911: Flow switch off error, When the switch is turned off within 10 seconds after a pump starts its operation (Re-operation is possible), E-913: Six times detection for Flow Switch Error (Re-operation is not possible), E-914: Error due to incorrect thermostat connection, E-917: Water Tank Sensor Configutation Error, UP: Trial operation incompleted (UnPrepared) – It will be cleared when trial operation was executed for 1 hour or when automatic inspection is completed. Sumsung cassette inverter error AD by the outdoor unit what does that mean, hi, thanks. Samsung Split Type, Multi System and VRF System AC Error Codes and Troubleshooting; Outdoor LED Display Error and Check Method (12K/18K/24K)-Samsung Split System Air Conditioning Outdoor LED Light Errors, Explanation: Communication error (unable to receive data), Main checking Point/Remark: Communication cable connection, Explanation: Communication error (outdoor cannot communicate), Main checking Point/Remark: Another indoor unit or indoor PCB, Explanation: Indoor unit room temperature sensor error (Open/Short), Main checking Point/Remark: Room temperature sensor, indoor PCB, Explanation: Indoor unit heat exchanger in temperature sensor error (Open/Short), Main checking Point/Remark: Heat exchanger in sensor, indoor PCB, Explanation: Indoor unit heat exchanger out temperature sensor error (Open/Short), Main checking Point/Remark: Heat exchanger out sensor, indoor PCB, Explanation: Indoor unit heat exchanger in temperature sensor detached, Main checking Point/Remark: Heat exchanger in sensor, Explanation: Indoor unit heat exchanger out temperature sensor detached, Main checking Point/Remark: Heat exchanger out sensor, Explanation: Indoor unit heat exchanger in & out temperature sensor detached, Main checking Point/Remark: Heat exchanger in & out sensor, Explanation: Indoor unit fan motor malfunction, Main checking Point/Remark: Fan motor and cable, Explanation: More than 2 indoor units cool and heat simultaneously, Main checking Point/Remark: Another indoor unit operation mode, Main checking Point/Remark: Cable connection (Indoor & Outdoor unit), Explanation: The number of indoor unit mismatched, Main checking Point/Remark: Cable connection (another indoor unit & outdoor unit), SW01(outdoor), Explanation: Compressor discharge sensor error(Short/Open), Main checking Point/Remark:  Outdoor unit, Main checking Point/Remark: Outdoor unit (Error code). SERIE COMMERCIALE D.12000-18000-24000SP-INV PLUS SERIE 2011 D.18000-24000-36000I-INV PLUS SERIE 2011 Che cosa sta ad indicare il codice E4 che appare sul display dei condizionatore? Trouble: The remote control does not operate, Trouble: The operation lamp continues to be flickering, Trouble: The immediate operation starts without control of remote control when plugged, Cause and reason: It is the case that the auto restart function works. All rights reserved. Unità Interne Polivalenti Mono-Multi > Le unità interne della gamma SIRIUS possono essere usate in configurazione Mono con le relative unità esterne o anche quali terminali per le unità Multi (SIRIUS 9, 12, 18 IU). FAQ sui condizionatori Samsung. Slave wired remote control installation error (when two slave wired remote controls are installed), Normal operation option setting error (when normal operation is selected with the wired remote control for a ventilation system (ERV) that does not support the normal operation option), Automatic operation option setting error (when automatic operation is selected with the wired remote control for a ventilation system (ERV) that does not support the automatic operation option), Only detected by products with a temperature sensor, Indoor unit room temperature sensor error (open or short), Indoor unit heat exchanger temperature sensor error (open or short), Option error (option wasn't set up or option data error), Remote Control on/off Outdoor Unit Power Reset, No communication for 2 minutes between indoor units (Communication error for more than 2 minutes), Indoor unit receiving the communication error from outdoor unit, When sending the communication error from the outdoor unit, the mismatching of the communication numbers and installed numbers after completion of tracking (Communication error for more than 2 minutes), Error of electronic expansion valve close, 2'nd detection of high temperature discharge, Compressor down due to 6'th detection of freezing. to admin..i also have error code e485 input current sensor error..im a retired hvac tech but have very little exp on mini splits..from what i have read says check power i did that its ok..then said replace pcb which i have on order..could anything else cause it as i dont have tools anymore and samsung tech wont talk to me.i had to order the board through a samsung service company here..could condenser fan motor cause that error?..i found a code for bad motor online e458 but i dont get that just e485. E-654: Data error on remote controller (Memory read/write error), My latest error code was E2 o3 or 03 which being the 3rd summer without it working clearly means its a piece of Crap. This website uses cookies to ensure you get the best experience Our, https://www.samsung.com/levant/air-conditioners, Actron AC Error Codes and Troubleshooting, Hitachi AC Error Codes and Troubleshooting, Godrej AC Error Codes and Troubleshooting, INDOOR MID, INDOOR IN PIPE-TH sensor error, DIS-TH(Discharge Temperature) Sensor Error, Prohibit Operation Condition Error (Heating), Prohibit Operation Condition Error (Cooling), Indoor unit room temperature sensor error (open / short), Indoor unit heat exchanger temperature sensor error (open / short), Lamp flickering-Lamp flickering-Lamp flickering, Lamp off -Lamp flickering-Lamp flickering, Abnormal communication error (Indoor - Outdoor unit), Lamp flickering-Lamp off -Lamp flickering, Outdoor unit temperature sensor error; Outdoor temp.-sensor, Deice temp.-sensor, OLP temp.-sensor, Discharge temp.-sensor, Heatsink temp.-sensor. Is the selected temperature too high? Oltre ai malfunzionamenti generici che qualsiasi condizionatore fisso può manifestare, vi sono delle anomalie o difetti, che sono tipici di ciascun condizionatore e vengono identificati attraverso … Funzioni Come si usa la modalità Good Sleep del climatizzatore? Codici errori climatizzatori samsung- Ricerca Tecniche per il controllo dell affidabilità dei caratteri (parità) o dei blocchi dei dati. Comment:*document.getElementById("comment").setAttribute( "id", "ade8436854dfd09f261f79fdbb4a5313" );document.getElementById("g2bf16c3b0").setAttribute( "id", "comment" ); Save my name, email, and website in this browser for the next time I comment. Permalink. Lower the selected temperature lower than the current one (during cooling). This category only includes cookies that ensures basic functionalities and security features of the website. Fixed compl Sump temperature sensor breakaway, Fixed comp2 Sump temperature sensor breakaway, Fixed comp3 Sump temperature sensor breakaway, Comp.1 Sump temperature sensor(Short or Open), Compressor down due to freeze protection control, System stop due to overload protection control, Comp, down by the sump protection control, Comp, down by the discharge temperature sensor, Heating operation restricted at outdoor temperature over TheatJiigh value (default: 30 °C), Cooling operation restricted at outdoor temperature below Tcooljow value (default 0°Q, Forbid an operation during heat mode with refrigerant charging operation when outdoor temperature is over 15°C, Start prohibition by refrigerant pressure error, Error due to operation failure of inverter compressor, System stop due to OLP temperature control, Error due to abnormal rotation of the compressor or unconnected wire of compressor, Error on DC-Link voltage sensor (Short or Open), Outdoor unit EEPROM Read/Write error (Option), Outdoor unit EEPROM Read/Write error (H/W), Error on IPM Heat Sink sensor of inverter 1 (Short or Open), Error on input current sensor of inverter 1 (Short or Open), Error due to mismatching capacity of indoor and outdoor unit, Switch option setting error(rvot applied), Indoor unit floating S/V error(When 1“ detection), Indoor unit EEV close failure(When 1“ detection), Indoor unit EEV open failure(When 1“ detection), Communication cables of indoor and outdoor units, Wired remote controller communication error, Wired remote controller cables, Wired remote controller, Communication error between indoor unit and outdoor unit, Communication error between wired remote controller and indoor unit, Operation LED and reservation LED flickering (1Hz period), Operation LED and filter LED flickering (1 Hz period), Reservation LED filter LED alternating flickering (1Hz period), Reservation LED and filter LED flickering (1Hz period), Indoor and outdoor communication abnormal, Operation LED and reservation LED alternating flickering (1Hz period), Wired remote controller communication abnormal, Check of departure of indoor temperature sensor, Check of indoor exchanger sensor departure, Check of outdoor exchanger sensor departure, When the electrical heater is over heated, Check of heater temperature sensor departure, Error of temperature sensor in the indoor unit (Open/5hort), Error of setting option switches for optional accessories, Indoor/Outdoor unit Communication Time Out Error 60 Packet Over data, Communication Error between Outdoor Main and Inverter Micom, (Occurred after 1 minute detection in Main and Inverter), Indoor Unit Eva in Sensor (Open/Short Error), Outdoor Temp Sensor Error (Open/Short Error), CONDTemp. and fortunately for lots of potential purchasers I have convinced them to choose anything rather than Samsung. Is the battery inserted in the wrong way(+, -)? any ideas what i have to check? AR18HSFNBWKN. Indoor unit is not installed in case of outside gearing (when the indoor unit is not detected after outside gearing option setting and tracking are finished).